63 Lake Monger Drive, Wembley

Was on display until 26 May 2021, 05:00 PM

  • Application numberDA21/0073
  • ProposalTwo x Four Storey Dwellings

63 Lake Monger Drive, Wembley 6014  View Map

Google Map

The Town has received an application proposing two x four-storey dwellings at the above-mentioned property.

The application is being advertised for the following reasons:

Residential Design Codes:

  • Clause 5.1.3 – Lot Boundary Setbacks:
  • Lot 2 (No. 63A): 1st Floor – Full Side (Ensuite to Balcony Planter) – setback 1m-1.6m from the west boundary.
  • Lot 1 (No. 63): 3rd Floor – Bed 2 to Bed 3 – setback 1.9m from the east boundary.
  • Clause 5.1.6 – Building Height:
  • Lot 1 (No. 63): Maximum height to the top of the flat roof: 7.9m.
  • Lot 2 (No. 63A): Maximum height to the top of the flat roof: 7.5m.
  • Clause 5.3.8 – Retaining Walls:
  • Lot 1 (No. 63): Maximum height of retaining walls on east boundary: 3.5m.
  • Lot 2 (No. 63A): Maximum height of retaining walls on west boundary: 2.2m.

Local Planning Policy 3.1 - Streetscape

  • Clause 4.1 – Garage Width:
  • Lot 2 (No. 63A): Maximum width of garage: 56.25% of total lot width.
  • Clause 5.1 – Street Walls and Fences:
  • Lot 1 (No. 63): Maximum width of letterbox wall: 1.3m.
  • Lot 2 (No. 63A): Maximum width of letterbox wall: 1.3m.
  • Clause 7.1 – Vehicle Access:
  • Lot 1 (No. 63): Maximum crossover width inclusive of splay: 5.7m.
  • Lot 2 (No. 63A): Maximum crossover width inclusive of splay: 5.6m.
  • Clause 5.4.1 – Visual Privacy:
  • Lot 1 (No. 63): 2nd Floor: Balcony setback 1.8m from east boundary.
  • 2nd Floor: Living + Dining setback 3.5m from east boundary.
  • 2nd Floor: Theatre windows on north and south elevation setback 4.9m from east boundary.
  • 3rd Floor: Balcony setback 6.3m from east boundary in lieu of 7.5m.
  • 3rd Floor: Bed 2 window on north elevation setback 3.1m from east boundary.
  • 4th Floor: Balcony setback 6.3m from east boundary. 
  • Lot 2 (No. 63A):
  • 2nd Floor: Balcony setback 2.7m from west boundary.
  • 3rd Floor: Balcony setback 2.6m from west boundary.
  • 4th Floor: Balcony setback 2.6m from west boundary. 

Local Planning Policy 1.1 – Minor Use and Development Exempt From Development Approval:

  • Clause 2 – Dividing Fencing:
  • Lot 1 (No. 63): Maximum height of dividing fencing on east boundary: 4.1m. 
  • Lot 2 (No. 63A): Maximum height of dividing fencing on west boundary: 3.3m. 

The Town can consider and approve applications that do not meet the deemed-to-comply provisions where the proposed development satisfies certain design principles.

To assist the Town in determining this application, you are invited to view the plans and comment on the parts of the development that do not meet the deemed-to-comply provisions and/or the proposed use.

A copy of the plans the associated documentation can be located through the links on the top right of this page. Alternatively, a hardcopy of this information can be viewed at the Town's Administration Centre, 1 Bold Park Drive, Floreat during normal operating hours.

Comments can be provided:

  • By email at mail@cambridge.wa.gov.au; or
  • By mail at Town of Cambridge, 1 Bold Park Drive, Floreat WA 6014.

Submissions are to be provided by 5:00pm on 26 May 2021

If you have any queries in relation to this matter, or would like to arrange an appointment to view the plans, please contact the Town on 9347 6000.